The reference standards used by our Technicians are maintained and calibrated at regular intervals. Below are several examples of reference standards used.
 |
Fluke 725 Multifunction Process Calibrator
-
Small, streamlined shape makes it easy to carry.
-
Rugged, reliable design stands up to field use.
-
Easy to read measure/source screen lets you view input and output simultaneously .
-
Measure volts, mA, RTDs, thermocouples, frequency, and ohms to test sensors and transmitters.
-
Source/simulate volts, mA, thermocouples , RTDs, frequency, ohms, and pressure to calibrate transmitters.
-
Measure/source pressure using any of 28 Fluke 700Pxx Pressure Modules.
-
Source mA with simultaneous pressure measurement to conduct valve and I/P tests.
-
Support flow meter testing with frequency and CPM functions.
-
Perform fast linearity tests with auto step and auto ramp features.
-
Power transmitters during test using loop supply with simultaneous mA measurement. |
|
|
|

|
Fluke 718 Pressure Calibrator
- Built-in pressure / vacuum hand pump, with vernier and bleed valve.
- Pressure measurement to 0.05% of full span, using an internal pressure sensor.
- Pressure measurement to 10,000 psi / 700 bar using any of the Fluke-700Pxx Pressure Modules.
- Wide range of selectable measurement units for pressure.
- Current measurement with 0.025% accuracy and 0.001 mA resolution.
- 24 volt loop power supply.
- Min-Max Hold functions.
- Compact size and weight.
- Simple, push-button user interface.
- Rugged and reliable, ideal for field use.
|
|
|
|

|
Fluke 700 PO1
-
Display pressure readings in any of 10 different pressure units you specify in the calibrator setup.
-
Rugged urethane molded case protects the module from rough handling and harsh conditions.
-
Features internal temperature compensation from 0ºC to 50ºC for full-accuracy performance .
-
Includes NIST-traceable calibration certificate.
-
Module can be calibrated locally using the Fluke 700PCK Pressure Calibration Kit, a PC, and a precision pressure source. |
|
|
|

|
Hart 1521 / 5613 Temperature Probe and Readout
-
Reads PRTs/RTDs to ±0.025°C and thermistors to ±0.005°C.
-
Model 1522 stores multiple data sets totaling 10,000 readings.
-
INFO-CON connector allows interchangeable use of calibrated probes.
-
INFO-CON eliminates errors from programming probe data. |
|
|
|

|
Vaisala HM 141
-
RH measurement range 0-100% RH
-
± 1% accuracy
-
Temperature measurement range -40 - +100 °C
-
Calculates dewpoint, wetbulb, temperature, absolute humidity and mixing ration.
-
Versatile and easy to use
-
Incorporates Vaisala HUMICAPSensor
-
Excellent stability
-
Data collection with serial line download capability
-
NIST traceable |
|
|
|

|
1433 Decade Box
|
|
|